Trax10227-LoRaWAN Ultrasonic Distance Sensor
Trax10227 LoRaWAN Ultrasonic Distance Sensor is designed for objects distance or level detection in harsh environments and transmitting data using LoRaWAN® technology. With this low power consumption technology, LoRaWAN sensor can work up to 10 years with 19000 mAh battery. Trax10227 LoRaWAN sensor is widely used for outdoor applications like flood monitoring, waste water management monitoring, etc.
Description
Trax10227 LoRaWAN Level detection sensor is designed for various applications like monitoring water levels, flood monitoring, snow level monitoring, agricultural fill level monitoring in grain, fertilizer or pellets silos. Users can manage all sensor data remotely on their own applications.
Simple and easy to use, configure your device via NFC. Built with IP66 waterproof enclosure for harsh environments.
Item | Aspect |
Wireless Transmission | Compliant with LoRaWAN Gateways and Network servers |
Frequency | CN470/IN865/RU864/EU868/US915/AU915/KR920/AS923 |
Tx Power | 16dBm(868)/20dBm(915)/19dBm(470) |
Sensitivity | -147dBm @300bps |
Mode | OTAA/ABP Class A |
Transmission range | Up to line of sight of 10km |
Measurement | |
Range | 0.3 – 5m/0.5-10m (Ordinary/Snow detection Version) |
Accuracy | ±1% FS |
Resolution | 1 mm |
Operation | |
Power On & Off | NFC, power button (Internal) |
Configuration | Mobile APP(via NFC) or PC software(via USB Type-C) |
Physical Characteristics | |
Power Supply | 19000 mAh Li-SOCL2 battery (ER34615) |
Battery Life* | 5.5 years (10 min interval, SF12), >10 years (10 min interval, SF7) |
Operating Temperature | –30°C to +65°C |
Relative Humidity | 0% to 100% (non-condensing) |
Ingress Protection | IP66 |
Dimension | 156.1 × 71 × 69.5 mm (6.1 × 2.8 × 2.7 in) |
Installation | Pole, wall or DIN Rail Mounting |
Approvals | |
Regulatory | CE, FCC, LoRaWAN ® Certified |
EMC | EN 55032, EN 55035 |
EMS | IEC 61000-4-2 Level 3, IEC 61000-4-3 Level 2, IEC 61000-4-8 Level 4 |
Radio Frequency | FCC Part 15B, FCC Part 15.247, EN 300 330, EN 301 489-1/3, EN 300 220-1/2 |
Safety | EN62368-1 |
Applications :
- Pipes and tanks pressure monitoring
- Oil & Gas monitoring
- Water leak detection
- Pump monitoring